
Product Overview and Features
The Diversitech CP-22 is a high-efficiency condensate pump designed for HVAC systems, featuring automatic condensate removal, a built-in tank, LED indicators, and an overflow safety switch for reliable operation.
1.1 Key Features of the Diversitech CP-22 Condensate Pump
The Diversitech CP-22 features automatic condensate removal, a built-in tank, and LED indicators for monitoring. It includes an overflow safety switch to prevent excess water buildup and metal hang tabs for secure installation. The pump offers a flow rate of 1.6 GPM at zero head and a maximum head height of 22 feet, making it ideal for high-efficiency HVAC systems producing acidic condensate.
1.2 Compatible Models and Applications
The Diversitech CP-22 is compatible with various HVAC systems, including high-efficiency condensing furnaces and boilers that produce acidic condensate. It works seamlessly with models like CP-22LP, CP-22T, and CP-22LPT, ensuring versatile application across different setups. The pump is designed for both residential and light commercial use, making it a reliable solution for condensate removal in diverse environments. Its compatibility ensures broad suitability for modern heating and cooling systems.
Installation and Setup
The Diversitech CP-22 installation involves connecting the pump to the HVAC system, mounting it securely, and wiring it according to the manual’s safety instructions for proper function.
2.1 Pre-Installation Checks and Requirements
Before installing the Diversitech CP-22, ensure the system voltage matches (120V/230V, 60Hz) and verify the current draw (1.9A/1.0A). Check the head height (22ft max) and flow rate (1.6GPM/1.0GPM) suitability. Ensure the pump’s physical dimensions (11.8×5.9×6.7 inches) fit the installation space and confirm compatibility with high-efficiency condensing furnaces or boilers producing acidic condensate.
2.2 Step-by-Step Installation Guide
Mount the CP-22 pump securely, ensuring level placement. Connect the 3/8″ flexible vinyl tubing to the barb fitting on the pump outlet. Wire the safety switch in series with the 24V thermostat circuit to enable A/C shutdown during overflow. Test the overflow switch by manually filling the tank with water. Power on the pump and verify proper operation, checking for LED indicators and flow rate. Ensure all connections are secure and inspect the system for leaks before finalizing the setup.
Safety Instructions and Precautions
Ensure proper wiring and avoid misalignment during reassembly. Check for overfill and inspect the overflow switch if the red LED indicates an alarm condition.
3.1 General Safety Guidelines
Always follow the installation manual to ensure safe operation. Check for overfill and ensure correct wiring to prevent hazards. Regularly inspect the overflow switch and tubing for proper function. Test the safety switch periodically and ensure the pump is placed on a level surface to avoid misalignment. Refer to the safety section of the manual for comprehensive guidelines.
3.2 Emergency Overflow Protection
The Diversitech CP-22 features an overflow safety switch that automatically shuts off the system in case of excess condensate, preventing damage. The red LED indicator signals an overflow condition, prompting immediate action. Regularly test the switch and ensure proper installation to maintain this critical safety feature. This mechanism ensures the pump operates safely and efficiently, protecting against potential overflows and system damage.
Technical Specifications
The Diversitech CP-22 offers a flow rate of 1.6 GPM at zero head and a maximum head height of 22 feet, ensuring efficient condensate removal in various HVAC applications.
4.1 Performance Metrics (Flow Rate, Head Height)
The Diversitech CP-22 delivers a flow rate of 1.6 gallons per minute at zero head and maintains a maximum head height of 22 feet, ensuring reliable and efficient condensate removal across various HVAC systems. This performance metric makes it suitable for high-efficiency condensing furnaces and boilers, which often produce acidic condensate, requiring a robust pumping solution to handle the output effectively.
4.2 Electrical and Physical Dimensions
The Diversitech CP-22 operates on 120/230 Volts at 60Hz, with a rated current draw of 1.9/1.0 Amps. Its compact design measures 11.8 x 5.9 x 6.7 inches, weighing 4.7 lbs. The inlet height from the base is 1.75 inches, ensuring easy installation and compatibility with various HVAC systems. These dimensions and electrical specs make it a versatile solution for condensate removal in residential and light-commercial applications.
Troubleshooting and Maintenance
Troubleshoot issues like alarms or overflow by checking the tank, ensuring proper wiring, and inspecting the overflow switch. Regularly clean the tank and tubing connections.
5.1 Common Issues and Solutions
Common issues include the red LED alarm for overflow, faulty overflow switches, or improper wiring. Solutions involve checking the tank level, ensuring the switch is aligned, and verifying connections. Clogged tubing or debris in the pump should be cleaned. Regular maintenance, like inspecting tubing and ensuring proper installation, prevents issues. Always refer to the manual for detailed troubleshooting steps to ensure optimal performance and safety.
5.2 Routine Maintenance Tips
Regularly inspect and clean the pump and tubing to prevent clogs. Check the overflow switch alignment and ensure proper wiring. Flush the tank periodically to remove debris. Replace worn-out parts promptly. Lubricate moving components as needed. Schedule annual professional inspections to maintain efficiency. Adhere to the maintenance schedule outlined in the manual to ensure long-term reliability and performance of the Diversitech CP-22 condensate pump.
Warranty and Support
DiversiTech offers a limited warranty covering defects in workmanship and materials. Dedicated customer service and support options are available for inquiries and troubleshooting.
6.1 Manufacturer Warranty Details
DiversiTech warrants the CP-22 condensate pump to be free of defects in workmanship and materials. The warranty covers pumps sold under the DiversiTech brand, ensuring reliability and performance. Specific terms and durations are outlined in the product manual, providing customers with peace of mind and protection against manufacturing issues.
6.2 Customer Service and Support Options
DiversiTech offers comprehensive customer support, including downloadable manuals, online troubleshooting guides, and dedicated technical assistance. Customers can access support via phone or email for installation and operational inquiries. Additionally, the website provides a wealth of resources, including FAQs and detailed product guides, ensuring users can resolve issues efficiently and maximize their pump’s performance.
Environmental Considerations
The Diversitech CP-22 is designed with eco-friendly materials and efficient operation, minimizing environmental impact. Proper disposal and recycling options are encouraged, aligning with sustainable practices.
7.1 Eco-Friendly Design and Efficiency
The Diversitech CP-22 features an eco-friendly design, minimizing environmental impact through energy-efficient operation and recyclable materials. Its high-efficiency performance reduces energy consumption and waste, promoting sustainable use.
- Energy-efficient motor design lowers power usage.
- Constructed with recyclable materials for reduced environmental footprint.
- Optimized flow rate and head height ensure minimal energy waste.
7.2 Proper Disposal and Recycling
Proper disposal and recycling of the Diversitech CP-22 are crucial for environmental sustainability. Dispose of the pump and its components responsibly, adhering to local regulations. Recycle metallic parts and safely handle electrical components to prevent contamination. Consult local recycling programs for guidance on processing recyclable materials. Ensure all hazardous materials are managed according to environmental standards to minimize ecological impact.
- Recycle metallic components whenever possible.
- Safely dispose of electrical and hazardous materials.
- Consult local recycling guidelines for proper procedures.
Online Resources and Downloads
The Diversitech CP-22 manual is available online as a PDF, offering a comprehensive guide for installation, operation, and safety. Access it easily for reference.
- Compatible with models: CP-22, CP-22LP, CP-22T, CP-22LPT.
8.1 Accessing the CP-22 Manual Online
The Diversitech CP-22 manual is readily available for download in PDF format, ensuring easy access to installation, safety, and operational guidelines. Users can find the manual on the manufacturer’s official website or through trusted online documentation platforms. The document covers all compatible models, including CP-22, CP-22LP, CP-22T, and CP-22LPT, providing detailed instructions for setup and troubleshooting. This convenient resource is designed to simplify the learning process for both professionals and homeowners.
- Compatible with multiple models: CP-22, CP-22LP, CP-22T, CP-22LPT.
8.2 Additional Documentation and Guides
Beyond the CP-22 manual, Diversitech offers supplementary guides, including installation instructions, technical specifications, and troubleshooting tips. These resources are available online in PDF format, ensuring comprehensive support for users. Additional documentation covers compatible models like CP-22LP, CP-22T, and CP-22LPT, providing detailed insights for professionals and homeowners. These guides simplify installation, maintenance, and problem-solving, ensuring optimal performance and safety for the condensate pump system.
- Includes installation and technical guides.
- Covers troubleshooting and maintenance tips;
The Diversitech CP-22 manual provides a comprehensive guide for efficient and safe operation. Regular maintenance and proper installation ensure optimal performance and longevity of the condensate pump system.
Always follow manufacturer guidelines for best results and extended product life.
9.1 Summary of Key Takeaways
The Diversitech CP-22 manual emphasizes proper installation, routine maintenance, and adherence to safety guidelines for optimal performance. Key features include automatic condensate removal, LED indicators, and overflow protection. Regular checks on wiring, tank levels, and pump functionality ensure reliability. Following the manufacturer’s instructions is crucial for extending the product’s lifespan and maintaining efficiency in condensate management systems.
9.2 Best Practices for Long-Term Use
For optimal performance, ensure regular maintenance, including inspecting wiring, tank levels, and pump functionality. Add Pro-Treat tablets to prevent corrosion and bacterial growth. Monitor LED indicators for alarm conditions and address promptly. Clean the pump and ensure proper drainage. Follow guidelines for replacement parts and electrical connections. Properly dispose of waste materials to maintain environmental standards and prolong the product’s lifespan.